Can Your Outlet Handle a Home Infrared Sauna? What to Check Before It Ships
Share
Before you order a sauna, go look at the outlet it's going to plug into. It's the step most people skip, and it's the one that decides whether setup day goes smoothly or ends with a tripped breaker.
Every sauna we carry lists its power needs on the product page. Here's how to read those numbers and what to check in your house before anything ships.
The quick math
Divide the watts by the volts and you get amps, and amps are what your breaker cares about. A standard US outlet runs at about 120 volts.
- CedarLuma 1-Person: 1170W on 110V, so roughly 10 amps.
- PioneerWorks 1 to 2 Person: 1700W on 110V, so roughly 14 to 15 amps.
- Hudson Bay 3-Person: 1805W, and the listing calls for 120V on a 20 amp circuit.
15 amp or 20 amp
Most household outlets sit on either a 15 amp or a 20 amp breaker. Open your electrical panel and the number is printed right on the breaker switch. A 20 amp outlet also usually has one slot shaped like a sideways T.
A sauna runs for a long stretch, and everything else on that same circuit adds to the load. If a hair dryer or a space heater shares the circuit, the breaker can trip halfway through a session. So the setup you want is a circuit with nothing else running on it while the sauna is on.
What I'd check before ordering
- Find the breaker for the outlet you plan to use and write down the number on it.
- Plug a lamp into that outlet, then turn breakers off one at a time to see what else goes dark with it. That tells you what shares the circuit.
- Plan to plug the sauna straight into the wall. Most sauna manuals say not to use an extension cord or power strip, so check yours when it arrives.
- Read the electrical section of the manual and follow the manufacturer's requirement over anything general in this post.
- If you're not sure about any of it, have a licensed electrician take a look. Adding a dedicated 20 amp circuit is a common job for them.
Matching the sauna to the outlet
If the only outlet in your spot is on a shared 15 amp circuit, the CedarLuma draws the least of the three. The PioneerWorks is close to what a 15 amp circuit can carry, so give it a circuit of its own. The Hudson Bay needs the 20 amp circuit the listing calls for, and it's a lot easier to sort that out before a 359 pound sauna shows up on a pallet.